Technical data
						Operation range 
					
					
						Pressure: 300...1100 hPa
Temperature: -40…85°C
				Temperature: -40…85°C
					Supply voltage VDDIO
Supply voltage VDD
				Supply voltage VDD
					1.2 ... 3.6 V
1.71 ... 3.6 V
				1.71 ... 3.6 V
					Interface
				
				
					I²C and SPI
				
				
					Average current consumption (typ.) (1Hz data refresh rate)
				
				
					1.8 μA @ 1 Hz (H, T)
2.8 μA @ 1 Hz (P, T)
3.6 μA @ 1 Hz (H, P, T)
T = temperature
				2.8 μA @ 1 Hz (P, T)
3.6 μA @ 1 Hz (H, P, T)
T = temperature
					Average current consumption in sleep mode
				
				
					0.1 μA
				
				
					Humidity sensor
Response time (τ63%) Accuracy tolerance
Hysteresis
				Response time (τ63%) Accuracy tolerance
Hysteresis
					1 s
±3% relative humidity
≤2% relative humidity
				±3% relative humidity
≤2% relative humidity
					Pressure sensor
RMS Noise
Sensitivity Error
 
Temperature coefficient offset
				RMS Noise
Sensitivity Error
Temperature coefficient offset
					0.2Pa (equiv. to 1.7cm)
±0.25% (equiv. to 1m at 400m height change)
 
±1.5Pa/K (equiv. to ±12.6cm at 1 °C temperature change)
				±0.25% (equiv. to 1m at 400m height change)
±1.5Pa/K (equiv. to ±12.6cm at 1 °C temperature change)
					RoHS compliant, halogen-free, MSL1
				
				
					Package dimensions
				
				
					8-Pin LGA with metal
2.5 x 2.5 x 0.93 mm³
				2.5 x 2.5 x 0.93 mm³
 
									
									 
									
									 
									 
									 
									 
									 
									 
					 
					 
					 
					 
					 
		 
		 
		 
		