Technical data
Operation range
Pressure: 300...1100 hPa
Temperature: -40…85°C
Temperature: -40…85°C
Supply voltage VDDIO
Supply voltage VDD
Supply voltage VDD
1.2 ... 3.6 V
1.71 ... 3.6 V
1.71 ... 3.6 V
Interface
I²C and SPI
Average current consumption (typ.) (1Hz data refresh rate)
1.8 μA @ 1 Hz (H, T)
2.8 μA @ 1 Hz (P, T)
3.6 μA @ 1 Hz (H, P, T)
T = temperature
2.8 μA @ 1 Hz (P, T)
3.6 μA @ 1 Hz (H, P, T)
T = temperature
Average current consumption in sleep mode
0.1 μA
Humidity sensor
Response time (τ63%) Accuracy tolerance
Hysteresis
Response time (τ63%) Accuracy tolerance
Hysteresis
1 s
±3% relative humidity
≤2% relative humidity
±3% relative humidity
≤2% relative humidity
Pressure sensor
RMS Noise
Sensitivity Error
Temperature coefficient offset
RMS Noise
Sensitivity Error
Temperature coefficient offset
0.2Pa (equiv. to 1.7cm)
±0.25% (equiv. to 1m at 400m height change)
±1.5Pa/K (equiv. to ±12.6cm at 1 °C temperature change)
±0.25% (equiv. to 1m at 400m height change)
±1.5Pa/K (equiv. to ±12.6cm at 1 °C temperature change)
RoHS compliant, halogen-free, MSL1
Package dimensions
8-Pin LGA with metal
2.5 x 2.5 x 0.93 mm³
2.5 x 2.5 x 0.93 mm³