Technical data
Operating voltage
1.8 V
Current consumption
Fuser2 (running CoreMark)
– Long Run mode (20 MHz)
– Turbo mode (50 MHz)
Sensor fusion (Hub+IMU) operation (calculating game rotation vector)
– 800 Hz ODR
– 100 Hz ODR
Standby current
Fuser2 (running CoreMark)
– Long Run mode (20 MHz)
– Turbo mode (50 MHz)
Sensor fusion (Hub+IMU) operation (calculating game rotation vector)
– 800 Hz ODR
– 100 Hz ODR
Standby current
950 µA
2.8 mA
1.2 mA
1.0 mA
8 µA
Sensor fusion performance
– Static accuracy (head., pitch, roll)
– Dynamic accuracy (head., pitch, roll)
– Calibration time
– Orientation stabilization time
2, 2, 2 degrees
7, 2, 2 degrees
<1 second
0.2 seconds

Do you want to find out more about the product?
Connect with our community of developers, share your expertise, and discover the latest in sensor technology. Join the Bosch Sensortec community now and access exclusive resources, insights, and discussionsConnect with our community of developers, share your expertise, and discover the latest in sensor technology. Join the Bosch Sensortec community now and access exklusive resources, insights and discussions.